Uplift Restraint Notches are enlarged for illustration purposes.
For non-structural application such as fence posts, mailbox posts, sign posts, etc.: A minimum of 2"
must be exposed from the top of the Green Post™ wrap to the top of the exposed earth or concrete
surface line. Ref. 1 For structural application requiring building code compliance such as post-frame
construction, interior or exterior support columns etc.: A minimum of 8" must be exposed from the top
of the Green Post™ wrap to the top of the exposed earth. Ref. 2 and 3 If a concrete slab is installed,
a minimum of 2" must be exposed from the top of the Green Post™ wrap to the top of the concrete
surface line. Ref. 4
Important: Never puncture or cut a Green Post™ wrap. Penetration of the wrap material below
"ground level" on the post by fasteners, bolts and nails is not permitted. Fastener penetration into the
wrap material is permitted 2" above the "ground level" on the post provided there is no direct exposure
to weather.